Skip to Content
  • IP Intercom
  • UPS
  • Cables
  • Monitors
Hikvision: DS-UPS3000 UPS 3000VA/1800W
Hikvision DS-UPS3000-AU 3KVA / 3000VA / 1800W Line-Interactive UPS -Uninterruptable Power Supply – Tower Case – LCD DIsplay – Compact Design
Features :-

3000VA / 1800W
LCD display
Wide input voltage range
Built-in AVR
Super fast charging
Overload and short circuit protection
USB port for remote control
Compact design

89.000 BD 89.0 BHD
Hikvision: DS-UPS1000 UPS 1000VA/600W
Compact size
Excellent microprocessor control guarantees high reliability

Parameters
Protection Method Overload, discharge, and overcharge protection
Operating Temperature And Humidity 0 °C to 40 °C (32 °F to 104 °F). Humidity 30% to 90% (non-condensing)
Weight Approx. 5.4 kg (11.9 lb)
Dimension 274 mm × 95 mm × 139 mm (10.79" × 3.74" × 5.47")
LED Indicator Working Mode (AC Mode): Solid green

Charging Mode (DC Mode): Solid red

Overloading Mode: Flashing yellow

Alarm Charging Mode (DC mode): Sounding every 10 seconds

Low Battery: Sounding every second

Overloading Mode: Sounding every 0.5 seconds

Fault: Continuously sounding

Storage Conditions -10 °C to 50 °C (14 °F to 122 °F). Humidity 20% to 95% (non-condensing)
Capacity 1000 VA / 600 W
Input Voltage Range 220 VAC to 240 VAC
Input Frequency Range 50/60 Hz
AC Voltage Regulation (Batt. Mode) 220 VAC to 240 VAC
Frequency Range (Batt. Mode) 50/60 Hz ± 0.5 Hz
Transfer Time DC to AC ≤ 10 ms; AC to DC ≤ 10 ms
Waveform (Batt. Mode)Charging Mode (DC Mode): PWM

POWER
Battery 12 V/9 Ah × 1
Rechargeable Typical recharge time: 10 to 16 hours
32.000 BD 32.0 BHD
Hikvision: DS-UPS600 UPS 600VA/360W
Capacity
600 VA / 360 W
Input Voltage Range
220 VAC to 240 VAC
Input Frequency Range
50/60 Hz
AC Voltage Regulation (Batt. Mode)
220 VAC to 240 VAC
Frequency Range (Batt. Mode)
50/60 Hz ± 0.5 Hz


Protection Method
Overload, discharge, and overcharge protection
Operating Temperature and Humidity
0 °C to 40 °C (32 °F to 104 °F). Humidity 30% to 90% (non-condensing)
Weight
Approx. 4.2 kg (9.26 lb)
Dimension
274 mm × 95 mm × 139 mm (10.79″ × 3.74″ × 5.47″)
LED Indicator
Working Mode (AC Mode): Solid green Charging Mode (DC Mode): Solid red Overloading Mode: Flashing yellow
Alarm
Charging Mode (DC mode): Sounding every 10 seconds Low Battery: Sounding every second Overloading Mode: Sounding every 0.5 seconds Fault: Continuously sounding
Storage Conditions
-10 °C to 50 °C (14 °F to 122 °F). Humidity 20% to 95% (non-condensing)

Capacity
600 VA / 360 W
Input Voltage Range
220 VAC to 240 VAC
Input Frequency Range
50/60 Hz
AC Voltage Regulation (Batt. Mode)
220 VAC to 240 VAC
Frequency Range (Batt. Mode)
50/60 Hz ± 0.5 Hz
Transfer Time
DC to AC ≤ 10 ms; AC to DC ≤ 10 ms
Waveform (Batt. Mode)
Charging Mode (DC Mode): PWM
POWER
Battery
12 V/7 Ah × 1
Rechargeable
Typical recharge time: 10 to 16 hours
25.000 BD 25.0 BHD